Reconstruction algorithm for sub-second X-ray tomographic microscopy of liquid water dynamics in polymer electrolyte fuel cells — ICTMS Committee Dep of Applied Maths Australian National University

Reconstruction algorithm for sub-second X-ray tomographic microscopy of liquid water dynamics in polymer electrolyte fuel cells (87)

Minna Bührer 1 2 , Hong Xu 3 , Jens Eller 3 , Felix Büchi 3 , Marco Stampanoni 1 2 , Federica Marone 1
  1. Swiss Light Source, Paul Scherrer Institut, Villigen, Switzerland
  2. Institute for Biomedical Engineering, University and ETH Zürich, Zürich, Switzerland
  3. Laboratory of Electrochemistry, Paul Scherrer Institut, Villigen, Switzerland

Sub-second X-ray tomographic microscopy is a powerful tool to gain understanding of water dynamics in fuel cells during operation. Reconstruction of these sparse, limited signal-to-noise ratio dynamic datasets requires advanced algorithmic solutions. We propose an extension of rSIRT-PWC [1] todifference sinograms, so minimizing time-consuming and error prone manual labor.

 

 

 

Full Paper